产品分类

DPGS43.160德国wika电接点差压表

 来源:www.xaqksm.com2021-01-19 11:28
 商家:西安秦控商贸
 联系电话:029-89390083 86696828
 传真:029-86696828
 在线客服:
在线业务 在线业务 在线业务
德国wika带电接点开关的差压表DPGS43.100, DPGS43.160 适合过程工业,全金属介质腔。

Models DPGS43.100, DPGS43.160
Version Process connections lower mount or lateral (option), highly corrosion-resistant solid metal
design, measuring cell protected against unauthorised access.
Overload resistance per EN 837-3
Nominal size in mm ■ 100
■ 160
Accuracy class 1.6
Option:
1.0 on request
Scale ranges 0 ... 16 mbar to 0 ... 250 mbar
0 ... 400 mbar to 0 ... 40 bar
other units (e.g. psi, kPa) available
or all other equivalent vacuum or combined pressure and vacuum ranges
Scale Single scale
Option:
■ Dual scale
■ Scale layout (e.g. linear pressure or square root incrementation)
Pressure limitation
Steady Full scale value
Fluctuating 0.9 x full scale value
Observe the recommendations for the use of mechanical pressure measuring systems in
accordance with EN 837-2
Overpressure safety and max. working
pressure (static pressure)
see table on page 3
Connection location Lower mount (radial)
Option:
lateral (right, left, front or back)
Process connection ■ G ¼ B female
■ G ½ B male
■ ½ NPT male
Other process connections via female or male threads on request
Permissible temperature 1)
Medium -20 ... +100 °C
Option:
Medium temperature > 100 °C on request
Ambient -20 ... +60 °C (with window from polycarbonate max. 80 °C)
Temperature effect When the temperature of the measuring system deviates from the reference
temperature (+20 °C): max. ±0.5 %/10 K of full scale value
Case ■ Version S1 per EN 837: With blow-out device in case back
■ Safety version S3 per EN 837: With solid baffle wall (Solidfront) and blow-out back
Case filling Without
Option:
With case filling
Venting of the media chamber With scale ranges ≤ 0.25 bar
Option:
With scale ranges ≥ 0.4 bar
1) For hazardous areas, the permissible temperature of the contact model 831 will exclusively apply (see page 5). These must not be exceeded at the instrument either (for details see operating instructions). If necessary, measures for cooling (e.g. syphon, instrumentation valve, etc.) have to be taken.
威卡DPGS43.100的功能特性
差压测量范围:0 … 1.6 kPa
高工作压力(静压),过压安全保护高达4 MPa
可提供可充液外壳,适用于高动态压力负载和高振动环境
提供带感应式电接点的仪表,用于危险区域
提供带开关电接点的仪表,适合PLC应用
威卡DPGS43.100的应用
控制和调节过程值
监控设备并控制电路通断
适用于过压较高的测量点
监测过滤器和泵
密封罐内的液位测量
威卡DPGS43.100的描述
无论何种情况下,如果您希望在本地显示过程压力的同时,对电路进行通断操作,switchGAUGE系列的DPGS43.1x0型压力表将是理想选择。
开关电接点(报警用电子式电接点)可根据仪表的指针位置接通和关断电气控制电路。开关电接点在全量程范围内可调(参见DIN 16085)。通常情况下,电接点都安装在表盘下面,只有少数是安装在表盘上面。仪表指针(实际值指针)可在整个量程范围内自由旋转,与设定无关。
设定指针可以通过窗口内的可拆卸调整键进行调整。
开关电接点不仅包含多个电接点,而且可以设置单个设定值。当实际值指针超过或低于设定值时,电接点便会进行切换。
该型号压力表根据DIN 16085标准制造,并且符合所有相关标准(如EN 837-3)和规范的安全要求,完全可用于现场测量高压容器的工作压力。
开关电接点包括磁助式电接点、干簧电阻链式电接点、感应式电接点和电子式电接点。其中感应式电接点可应用与危险区域。电子式和干簧电阻链式电接点可用于用于触发PLC。
DPGS43.100威卡电接点差压表